The Pullcord Anti-Ligature Kit is ideal for applications where extra safety precautions are needed to minimize the risk of resident self-harm. The pullcord is designed to break with a low breaking force without elongation yet provides a secure connection point to the pullcord station. Three ergonomically designed pull rings accommodate the placement of the resident's hand or other assistive devices at multiple intervals on the pull cord. The pullcord and pull ring contain an anti-microbial additive for infection control.
The Pullcord Anti-Ligature Kit is compatible with all Responder pullcord stations. The Pullcord Anti-Ligature Kit can be installed on existing pullcord stations without removing the station from the wall allowing easy conversion with minimal disruption in the patient room. The word "Rauland" is indelibly printed along the pullcord to distinguish it from standard Rauland pullcords.
• Anti-ligature cord breaks at 13 Ibf +/- 3 Ibf (57.8 N -r/-13.4 N)
• Pull ring designed to accommodate various disabilities
• Pullcord and pull rings contain an anti-microbial additive
• Up to three pull rings allow placement on cord at multiple intervals
• Compatible with all Responder pullcord stations
• Quick and easy field replacement for existing pullcords
• Enhanced Flexibility: Wireless communication removes the need for cumbersome bed cables, reducing the risk of wear and tear, and allowing for easier bed movement within patient rooms.
• Improved Patient Safety: Continual monitoring of Bed Exit and patient calls ensures that staff are immediately alerted to any critical situations, improving response time and patient care.
• Easy Installation and Integration: The device plugs into standard receptacles, integrating effortlessly with existing systems, which minimizes installation time and eliminates the need for system overhauls.
• User-Friendly Operation: The system’s linking and unlinking process is simple, with visual and audible feedback confirming successful connections, reducing the chance of errors.
• Maintenance and Cost Efficiency: The low battery warning feature ensures that the system is always operational, and quick field replacement of pullcords reduces downtime and maintenance costs.
• Hygiene and Infection Control: The anti-microbial additives in the pullcord and pull rings help maintain a clean environment, essential for healthcare settings where hygiene is a top priority.
• Versatile Placement: The adjustable pull rings offer flexibility in positioning, making the system adaptable to individual patient needs and varying room configurations.
• Cord Material: TPU Thermoplastic Polyurethane Elastomer Polyether Base with nylon core and anti-microbial additive
• Cord Length: 10 ft (3.04 m)
• Cord Breakage: 13 Ibf +/- 3 Ibf (57.8 N +/- 13.4 N)
• Pull ring Material: PC/ABS with anti-microbial additive
• Pull ring Dimensions: W: 3.43” (87.12 mm), H: 3.13” (79.48 mm), D: 0.40" (10.20 mm)
• Pull ring Quantity: 3
• Certification: CE, RoHS/WEEE
• The 350033 design satisfies the applicable advice and guidance of the Health Technical Memorandum HTM08-03: Bedhead Services. In addition, the cord is designed to break at lower force than the requirement specified in AS 3811 Hard-Wired Patient Alarm Systems.