Home       Schedule a Call

National Supplier of Nurse Call & Life Safety Systems

Rauland Responder 5000 R5KDC46 Domeless 4 audio 6 station-Pre-Owned

SKU
R5KDC46-REF
$310.00

This item is for sale is a Rauland 5000 Domeless Audio Station- PRE-OWNED


OR
  • INFO
  • SPECS
  • RELATED
  • Rauland Responder 5000 R5KDC46 Domeless 4 audio 6 station-Pre-Owned

    View Other Rauland Nurse Call REPLACEMENT Parts

    View Rauland Nurse Call REPAIR Options

    The R5KDC46 provides the connection points for up tosix (6) room stations, 4 of which can contain audio. It istypically located where a corridor light is not needed ordesired. The domeless controller can be mounted in a wallcavity or ceiling outside of the resident room. Other corridorlights can be programmed to reflect calls placed on residentstations connected to the domeless controller. With theaddition of the Relay Output module, the R5KDC46 canprovide four (4) dry relay contact outputs to drive externaldevices.

    The domeless controller will operate in a default fail-safemode if communication with the Main System Controller isinterrupted. It also contains a status LED visible to servicepersonnel to indicate the device status. The mounting plateaccommodates a variety of backboxes. The domelesscontroller is continuously supervised for both power anddata. A "Trouble" message will annunciate at the coveringconsole(s) if the controller is removed from the system orbecomes non-functional.

    Features

    • Accommodates six (6) station connection points of which 4 (4) may contain audio
    • Designed for use where a corridor light is not needed
    • Adds additional room stations in a ward environment
    • Provides connection point for Output Driver boards
    • Other corridor lights can be programmed to reflect calls placed on resident stations connected to a domeless controller
    • Serves as a control module for room stations
    • Status LED indicates domeless controller operational status
    • Fail-safe operation in event of loss of data communications
    • Mounting plate design accommodates a variety of single and dual gang backboxes

    Specifications

    • Power Requirements: 15.5V DC @ 300 mA (max)
    • Weight: 959 kgs (2.1 lbs)
    • Size: W: 15.24 cm (6.0") H: 19.05 cm (7.5") D: 9.52 cm (3.75")
    • Housing and Finish: 20 gauge steel, painted gray
    • Controls/Indicators: One (1) status LED
    • Backbox Requirement: The mounting hole pattern on the housing allows for North American, South American, and European style single and dual gang backboxes. The metal housing also permits the R5KDC46 to be located above ceiling tiles or to be placed into a wall.
    • Terminations: Plug on connectors, CAT 5 and CAT 6 compatible 
    • Certifications: Designed for compliance to ANSI/UL 1069, IEC 60950, CE, RoHS / WEEE Compliant. Assembled in a U.S. FDA registered facility.